What was found
FUSELAGE EXTERIOR INTERIM REPAIR AT HOLD OPEN HOOK AREA STA 14.000 L-15L TO L-16L. PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 DATED 08-07-06, DWG NR AB78-53-R02 REV IR DATED 07-13-06. REMOVED EXISTING NON STANDARD REPAIR IAW SRM 51-1-21, SRM 51-1-20D, SRM 51-3-0. CUT OUT AND FABRICATED REPAIR DOUBLER (AL7075T6 0.071") (2EA) INTERNAL FINGER DOUBLER (AL7075T6 0.032") AND FILLER (AL7075T6 0.050") IAW DWG AB78-53-R02. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW SRM 51-1-11. INSTALLED REPAIR PARTS IAW SRM 51-1-21, DWG AB78-53-R02, SRM 51-1-20D, SRM 51-3-0, SRM 51-3-1.