What was found
D-CARGO DOOR JAMB FWD LWR CORNER 0.500 INCH CRACK STA 1400.000 L-32R (MAJOR REPAIR) AND CORROSION DAMAGE ON LWR FUS SKIN. PERFORMED MAJOR REPAIR IAW SRM 53-4-1 FIG 17A, DWG DACO 5779936. REMOVED CORROSION IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW SRM 53-2-0 PG 2P. REMOVED DAMAGED PLATING IAW SRM 53-1-0, SRM 51-1-21, SRM 51-1-20D. CLEANED, TREATED AND PRIMED AREA AND NEW PLATING IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW SRM 51-1-11. INSTALLED NEW PLATING IAW SRM 53-4-1 FIG 17A, DACO DWG 5779936, SRM 51-1-21, SRM 51-1-20D, SRM 51-3-0, SRM 51-3-1 (TORQUE).