As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHILE IN "C" CHECK, FRAME STA 480, SHEAR TIE AT FRAME IS CRACKED BETWEEN STR 16L AND STR 17L. REMOVED FASTENERS AND CRACKED ANGLE AT STA 480 BETWEEN STR 16L AND 17L IAW B727 SRM 51-30-2. FABRICATED ANGLE FROM 7075T6 .040 PO NR 9004940 APPROX DIM. 6" BY 2" IAW B727 SRM 51-40-3 FIG 1 AND 51-20-1 FIG 7. PRIMED ANGLE IAW B727 SRM 51-10-2. INSTALLED ANGLE AT STA 480 BETWEEN STR 16L AND 17L IAW B727 SRM 51-30-2.