What was found
WHILE IN "C", FWD CARGO COMPT STA 600 +4" REINFORCEMENT FRAME IS DENTED ABOVE STR 24L. TRIMMED OUT DAMAGED (DIM.3" BY 1.25") IAW B727 SRM 51-10-1. FABRICATED REPAIR CHANNEL FROM 7075-0 .090 PO NR 7185240 (DIM 23" BY 5") IAW B727 SRM 53-10-4 FIG 1. HEAT TREATED CHANNEL TO 7075T6 IAW FAS ENGINEERING REPORT NR 2-37153-801 REV 1. TREATED AND PRIMED REPAIR CHANNEL IAW B727 SRM 51-10-2 C/W HFEC IAW B727 NDTM PT6 51-00-00 FIG 23. NO CRACKS NOTED. ENLARGED TRIMMED AREA BY .040 IAW B727 51-10-1. INSTALLED REPAIR CHANNEL IAW B727 SRM 51-30-2.