What was found
AFT PIT LT 950A-950B AT STR-25L AND 24L INTERCOSTAL WEB ARE DENTED AT TOP AREA. FOUND BOTH INTERCOSTAL WEBS (STR 24L AND 25L) CRACKED AT DENTED AREA IAW B727 SRM 51-10-1. STOP DRILLED CRACKS (0.0250" DIAMETER) IAW B727 SRM 51-10-1. FABRICATED 2EA ANGLE REPAIRS FROM 2024-T3 0.050" PO NR 9002463 (DIM 4 BY 2.5) IAW B727 SRM 53-10-2 FIG 5 AND 51-40-3 FIG 1. TREATED AND PRIMED AREA AND ANGLES IAW B727 SRM 51-10-2 AND INSTALLED REPAIR ANGLES AT AFT PIT LT BS 950A-950B AT STRS 24L AND 25L INTERCOSTAL WEBS TOP AFT AREA IAW B727 SRM 51-40-3 FIG 1 AND 51-30-2.