What was found
AFT PIT RT BS 950A PLUS 4" INTERCOSTAL WEB CRACKED, CORRODED AT AREA UNDERNEATH SIDE WALL PANEL BETWEEN STR-26R AND STR-27R. REMOVED CRACKED ANGLE IAW B727 SRM 51-30-2. FABRICATED NEW ANGLE FROM 2024-T3 0.063" PO NR 9004940 (DIM 18 1/8" BY 1 1/2") IAW B727 SRM 53-10-2 FIG 5 AND 51-10-3 AND 51-20-1. TREATED AND PRIMED AREA AND NEW ANGLE W B727 SRM 51-10-2 AND INSTALLED NEW ANGLE AT AFT PIT RT BS 950A PLUS 4" INTERCOSTAL WEB IAW B727 SRM 51-30-2.