What was found
AFT PIT, LT BS 950F, FRAME DENTED BETWEEN STR 23L AND 26L. CUT OUT DAMAGED AREAS, 2 EA, 1.5" BY 1", FABRICATED ANGLE REPAIR FROM 7075-T0, .071" BY 12" BY 4" BY 1", IAW B727 SRM 53-10-2 FIG 5 AND 51-40-3 FIG 1. HEAT TREATED REPAIR ANGLE TO T6 CONDITION IAW F.A.S.I. ER NR 2-37153-801 REV A. TREATED, PRIMED, AND INSTALLED REPAIR ANGLE PER B727 SRM 51-10-2 AND 51-40-3 FIG 1.