What was found
SFT PIT STRINGER 30 BETWEEN BS 950+10" AND 950A, IS CORRODED. REMOVED "T" CHORD (INTERCOSTAL), CORROSION ON CHORD EXCEEDED LIMITS PER B727 SRM 53-10-1 FIG 1. LOCATED, DRILLED, TREATED, PRIMED, AND INSTALLED NEW INTERCOSTAL "T" CHORD P/N 69-44177-1 AT BS 950 BETWEEN STR 29L AND 29R, PER B727 SRM 51-30-5, 51-10-1, 51-10-2, AND 51-30-2.