What was found
AFT PIT, BS 1030 FRAME DENTED BETWEEN STR 25L AND 26L. CUT OUT DENTED AREA, 1.5" BY .875", FABRICATED REPAIR DOUBLER FROM 7075-T0, .071" BY 11" BY 4", PO NR 9004690, PER B727 SRM 51-40-3 FIG 1 AND 53-10-2 FIG 5. HEAT TREATED TO T-6 CONDITION PER FASI ER NR 2-37153-801 REV A. TREATED, PRIMED, AND INSTALLED PER B727 SRM 51-10-2 AND 51-40-3 FIG 1.