What was found
GOUGE NOTED AT FWD UPPER CORNER OF C2 DOOR CUT-OUT, EXT FUSE, AT BS 950E ABOVE STR 18R. REMOVED ADJACENT FASTENERS, AND BLENDED OUT GOUGE: ORIGINAL MATERIAL 0.138, MAT REMOVED 0.028, BLEND EXCEEDS LIMITS PER B727 SRM 53-30-1FIG 1 AND 2. FABRICATED REPAIR DOUBLER FROM 2024-T3, .080 BY 17 BY 16.5, PO NR 9005551, PER BOEING SERVICE REQUEST (BSR) NR 1-460569907. TREATED, PRIMED, AND INSTALLED REPAIR DOUBLER PER B727 SRM 51-10-2 , BSR NR 1-460569907, AND BAC SUPPLIED FORM 8100-9 DATED 8/7/2007.