What was found
STRINGER 26R CORRODED AT BS 480. CORROSION FOUND TO EXIST ON STR SPLICE AT BS 480. REMOVED, STR SPLICE, FABRICATED NEW SPLICE FROM 7075-T6, .040" BY 13" BY 5", PO NR 9004940, PER B727 SRM 53-10-2 FIG 9, 51-10-3, AND 51-20-1. TREATED, PRIMED, AND INSTALLED NEW STR SPLICE SECTION PER B727 SRM 51-10-2 AND 51-30-2.