What was found
DENT AT FRAME BS 950D ABOVE STRINGER 26L AFT PIT. CUT OUT DAMAGE AREA DIMENSION IAW B-727 SRM 53-10-4 FIGURE 1. FABRICATED NEW FRAME REPAIR IAW FORM FAS 1115 REV 11. LOCATED AND DRILLED NEW FRAME REPAIR IAW B-727 SRM 53-10-4 FIGURE 1 AND 51-30-5. TREATED AND PRIMED NEW FRAME IAW B-727 SRM 51-10-2 AND INSTALLED NEW FRAME REPAIR AT BS 950D IAW B-727 SRM 51-30-2.