What was found
BS 950C BETWEEN STRINGER 28L AND 29L FRAME SHEAR TIE DAMAGED. CUT OUT DAMAGED SECTION APPROXIMATE DIMENSION 6.75" BY 2" IAW B-727 SRM 53-10-4 FIGURE 15 AND SRM 51-10-1. FABRICATED SHEAR TIE REPAIR FROM 7075-O 0.071" APPROXIMATE DIMENSION 6.75" BY 2" IAW B-727 SRM 53-10-4 FIGURE 15 AND SRM 53-10-2 FIGURE 5. HEAT TREATED MATERIAL TO T6 CONDITION IAW FAS ER NR 2-37153-801 REV A. TREATED AND PRIMED PARTS IAW B-727 SRM 51-10-2. INSTALLED SHEAR TIE REPAIR AT STATION 950C STRINGER 29L IAW B-727 SRM 53-10-4 FIGURE 15 AND SRM 51-30-2.