What was found
RIGHT FUSELAGE CHAFFED AT BS 720D + 10" STRINGER 19R. CUT OUT DAMAGED AREA 6.75" BY 2.75" IAW B-727 SRM 53-30-3 FIGURE 6. FABRICATED DOUBLER REPAIR 2024-T3 0.071" PO NR 9005922 DIMENSION: 15.5" BY 9", STRUCTURAL FILLER 2024-T3 0.063" PO NR 9006027 DIMENSION: 14.5" BY 4.25" AND FILLER 2024-T3 0.063" PO NR 9006027 DIMENSION: 6.75" BY 2.75" IAW B-727 SRM 53-30-3 FIGURE 6 AND SRM 53-30-2 FIGURE 2. TREATED AND PRIMED IAW B-727 SRM 51-10-2 AND INSTALLED REPAIR ON RIGHT FUSELAGE BS 720D + 10" STRINGER 19R IAW B-727 SRM 51-30-2, 53-30-3 FIGURE 6 AND 53-30-2 FIGURE 2.