What was found
FORWARD CARGO COMPARTMENT STRINGER 26R IS HEAVILY CORRODED BETWEEN STATION 720F TO 740. CUT OUT DAMAGE AREA 9.5" AT STRINGER 26R BETWEEN STATION 720F - 740 IAW B-727 SRM 53-10-3 FIGURE 1. FABRICATED NEW SECTION, MATERIAL USED BAC 1498-147 0.090" 7075-T6 PO NR 7332258 DIMENSION 9.25" AND SPLICED MATERIAL USED BAC 1498-13107075-T6 PO NR 7332231 DIMENSION 11.25" IAW B-727 SRM 53-10-3 FIGURE 1 AND 53-10-2 FIGURE 5. TREATED AND PRIMED IAW B-727 SRM 51-10-2. INSTALLED REPAIR PARTS IAW B-727 SRM 53-10-3 FIGURE 1 AND 51-30-2.