What was found
DENT AFT PIT AT FRAME BS 1050 ABOVE STRINGER 26R. REMOVED FASTENERS AS REQUIRED FOR ACCESS IAW SRM 51-30-2. CUT OUT DAMAGED AREA DIMENSION 1" BY 1.5: AND FABRICATED REPAIR ANGLE IAW SRM 51-40-3 AND M/I 53-10-2 FIGURE 9. HEAT TREATED MATERIAL TO T6 0.071 CONDITION IAW FAS REPORT NR 2-37153-801 REV A. TREATED AND PRIMED IAW B-727 SRM 51-10-2. INSTALLED ANGLE REPAIR ON FRAME BS 1050 ABOVE STRINGER 26R IAW B-727 SRM 51-30-2.