What was found
DENT, AFT PIT AT FRAME BS 1070 ABOVE STRINGER 26R. CUT OUT DAMAGED AREA APPROXIMATE DIMENSTION 1: BY 1: IAW B-727 SRM 51-40-2 FIGURE 1. FABRICATED FRAME REPAIR DOUBLER FROM 7075-0 0.071" PO NR 724711 APPROXIMATE DIMENSION 10" BY 4.5" IAW B-727 SRM 51-40-2 FIGURE 1 AND 53-10-2 FIGURE 5. HEAT TREATED MATERIAL TO T6 CONDITION IAW FAS ER NR 2-37153-801 REV A. INSTALLED REPAIR DOUBLER AT FRAME BS 1070 ABOVE STRINGER 26R IAW B-727 SRM 51-40-3 FIGURE 1 AND SRM 51-30-2.