What was found
MULTIPLE DENTS AFT PIT FRAME BS 950F BETWEEN STRINGER 26L AND 25L. CUT OUT DAMAGED AREAS (2 EACH DIMENSION 1" BY 1"). FABRICATED REPAIR ANGLE FROM 7075-0 0.080" PO NR 9005665 (DIMENSION 17" BY 5.5") IAW B-727 SRM 53-10-2 FIGURE 5 AND 51-40-3 FIGURE 1. HEAT TREATED ANGLE TO T6 IAW FAS ENGINEERING REPORT NR 2-37153-801 REVA. TREATED AND PRIMED NEW ANGLE IAW B-727 SRM 51-10-2 AND INSTALLED REPAIR ANGLE AT AFT PIT FRAME BS 950F BETWEEN STRINGER 25L AND 26L IAW B-727 SRM 51-30-2 AND 51-40-3 FIGURE 1.