What was found
DENTED FRAME AFT PIT BS 1110 ABOVE STRINGER 25R. REMOVED PREVIOUS REPAIR IAW B-727 SRM 51-30-2. CUT OUT DAMAGE (DIMENSION 1" BY 1") AND FABRICATED REPAIR ANGLE FROM 7075-0 0.071" PO NR 7247111 (DIMENSION 16" NR 4.25") IAW B-727 SRM 51-40-3 FIGURE 1 AND 53-10-2 FIGURE 5. HEAT TREATED ANGLE FROM 7075-0 TO 7075-T6 IAW FAS ENGINEERING REPORT NR 2-37153-801 REV A. TREATED AND PRIMED PARTS AND AREA IAW B-727 SRM 51-10-2. INSTALLED REPAIR PARTS IAW B-727 SRM 51-30-2 AND 51-40-3 FIGURE 1.