What was found
WHILE AT FLIGHTSTAR FOR A "C" CHECK, FUSELAGE FRAME DENTED BS 640 BETWEEN 16R-17R. CUT OUT DAMAGE AREA DIM 1.5" AND 1" BY 1" IAW B727 SRM 51-40-03 FIG 1. FAB ANGLE REPAIR FROM 7075-T6 .050 PO NR 9005138 IAW B727 SRM 53-10-02 AND 51-40-03 FIG 1, LOCATED AND DRILLED IAW B 727 SRM 51-30-05. ALODINE AND PRIMED ANGLE AND AREA IAW B 727 SRM 51-10-02. INSTALLED ANGLE REPAIR IAW B727 SRM 51-30-02 AND 51-40-03 FIG 1.