What was found
FRAME DENTED AT BS 990 JUST ABOVE STRINGER 27L. CUT DAMAGE AREA AT BS 990 ABOVE STRINGER 27L DIMENSION 1" BY .75" IAW B-727 SRM 51-40-3 FIGURE 1. FABRICATED FRAME REPAIR FROM 7075-O PO NR 9004690 DIMENSION 9" BY 4" IAW B-727 SRM 51-40-3 FIGURE 1. HEAT TREATED PART FROM 7075-0 TO 7075-T6 IAW FAS REPORT NR 2-37153-801 REV A FORM NR FAS0115 REV 11. PART AND AREA TREATED AND PRIMED IAW B-727 SRM 51-10-2. FRAME REPAIR INSTALLED AT BS 990 ABOVE STRINGER 27L IAW B-727 SRM 51-40-3 FIGURE 1 AND 53-10-2 FIGURE 5.