What was found
2 EACH DENTS HAVE INDICATION OF CRACK HFEC INSPECTION. REMOVED PREVIOUS REPAIR AT FUSELAGE SKIN RIGHT 1342 STRINGER 19R IAW B-727 SRM 51-30-2. FABRICATED DOUBLER REPAIR MATERIAL USED 2024-T3 0.063" PO NR 9005773 DIMENSION 11.5" BY 5.5" IAW B-727 SRM 54-30-3 FIGURE 7 AND 54-30-2 FIGURE 4. TREATED AND PRIMED PART AND AREA IAW B-727 SRM 51-10-2. INSTALLED NEW DOUBLER IAW B-727 SRM 51-30-2 AND 54-30-3 FIGURE 7.