What was found
IN "C" CHECK, FWD CARGO COMPT FRAME STA 700 HAS 3 DENTS AT UPPER FLANGE BETWEEN STR 24L-25L. CUT OUT DAMAGED AREA APPROX 1" BY 3/4" IAW B727 SRM 51-40-3 FIG 1. FAB REPAIR ANGLE FROM 7075-0 .063 PO NR 9004384 APPROX DIM 11.7" BY 4" IAW B727 SRM 51-40-3 FIG 1 AND SRM 53-10-2 FIG 3. HEAT TREATED MAT. TO T6 CONDITION IAW FAS FORM NR FAS0115 REV 10. INSTALLED REPAIR ANGLE AT FWD CARGO COMPT BS 700 STR 24L-25L IAW B727 SRM 51-40-3 FIG 1.