What was found
NR 4 SLAT DENTED ON L/EDGE, LWS 380. CUT OUT DAMAGE, FABRICATED DOUBLER FROM 2024-T0, .080" BY 9" BY 4" (2 EA), PO NR 509622; FABRICATED FILLER FROM 2024-T3, .063" BY 4.75" BY 3.5", PO NR 9003641, PER B727 SRM 57-50-2 FIG 2 AND 57-50-3 FIG 1. HEAT TREATED 2024-T0 MATERIAL TO T4 PER FASI ENG REPORT NR 2-37153-801 REV A. TREATED, PRIMED, AND INSTALLED REPAIR PARTS PER B727 SRM 51-10-2, AND 57-50-3 FIG 1.