What was found
LT INBD FLAP, AFT FLAP INBD SIDE HAS SMALL DELAMINATION LWBL 89.6 TO 96.6, 10 TO 15 ABOVE T/E. REMOVED DAMAGED AREA 3.5 BY 3.6, CLEANED AND PREPPED AREA TO BE REPAIRED IAW B727 SRM 51-40-20, PARA 7, FIG 3. FABRICATED FILLER 3.5 BY 3.6 AND DOUBLER 6.5 BY 5.1 FROM .012, 7075-T6. ANODIZED, PRIMED AND APPLIED ADHESIVE FILM IAW B727 SRM 51-40-20, 51-40-24, FIG 1 AND 57-50-2, FIG 3. INSTALLED REPAIR PARTS, CURED AND FINISHED REPAIR AREA IAW B727 SRM 51-40-20, PARA 20, 22 AND 51-40-24, FIG 1.