What was found
EXTERNAL FUSELAGE BS 475 AT STR 8R HAS A LIGHTNING BURN ON A FASTENER. BLENDED OUT AREA OF LIGHTNING STRIKE IAW B727 SRM 53-30-3, FIG 20. MATERIAL LOSS OVER 30 PERCENT AND LIGHTNING STRIKE STILL PRESENT AND OUT OF LIMITS IAW B727 SRM 53-30-1. CUT OUT DAMAGED AREA DIM 1.5 BY 1.25 IAW B727 SRM 53-30-3, FIG 3. HFEC COMPLIED WITH IN CUT OUT AREA, NO CRACKS NOTED IAW B727 NDTM PT.6 51-00-00, FIG 23. FABRICATED DOUBLER REPAIR FROM .050, 2024T3, DIM 9 BY 6.50 AND FILLER FROM .040, 2024T3, DIM 1.5 BY 1.25 IAW B727 SRM 53-30-2, FIG 2 AND 53-30-3, FIG 3. TREATED, PRIMED AND INSTALLED REPAIR IAW B727 SRM 51-10-2, 51-30-2 AND 53-30-3, FIG 3.