What was found
WHILE IN "A" CHECK, RT INBD TE FLAP PREVIOUS REPAIR HAS CHAFFING ON LE OF FOREFLAP. REMOVED PREVIOUS REPAIR IAW B727 SRM 51-30-2. FABRICATED NEW DOUBLER FROM 2024T3 .063 PO NR 9005138 DIM 5 1/4" BY 4 1/4' IAW B727 SRM 57-50-04 FIG 1 AND 57-50-2 FIG 3. TREATED AND PRIMED DOUBLER IAW B727 SRM 51-10-2 AND INSTALLED NEW REPAIR DOUBLER AT RT IB TE FOREFLAP (AT WBL 243) IAW B727 SRM 57-50-4 FIG 1 AND 51-30-2.