What was found
DENT AT BS 1030 FRAME, JUST OUTBOARD OF STRINGER 27R. REMOVED FASTENERS FROM BS 1030 IAW B-727 SRM 51-30-2, CUT OUT DAMAGED AREAS AND FABRICATED REPAIR ANGLE DOUBLER IAW B-727 SRM 51-40-3 FIGURE 1 AND SRM 53-10-2 FIGURE 5. HEAT TREATED REPAIR ANGLE TO T6 CONDITION IAW FAS ENGINEERING REPORT NR 2-37153-801 REV A, TREATED AND PRIMED PARTS IAW B-72 SRM 51-10-2. INSTALLED REPAIR ANGLE AT BS 1030 FRAME STRINGER 27R IAW B-727 SRM 51-30-2 AND 51-40-2 FIGURE 1.