What was found
RIGHT ELEVATOR LOWER SKIN PUNCTURED AT ELEVATOR STATION 35.55. REMOVED FASTENERS AT RIGHT ELEVATOR LOWER SKIN STATION 35.55 IAW B-727 SRM 51-30-2, CUT OUT SKIN DAMAGED IAW B-727 SRM 55-20-3 FIG 4. FABRICATED REPAIR DOUBLER IAW B-727 SRM 55-20-3 FIGURE 4. INSTALLED REPAIR DOUBLER AT RIGHT ELEVATOR LOWER SKIN STATION 35.55 IAW B-727 SRM 55-20-3 FIGURE 4. ELEVATOR REBALANCING NOT REQUIRED IAW B-727 SRM 51-80-7, ELEVATOR MOMENT 120.12, REPAIR MOMENT .48 LBS, NEW ELEVATOR MOMENT 120.6 IS WITHIN LIMIT IAW B-727 SRM 51-80-7.