What was found
FOUND TWO DENTS ON UPPER RUDDER LT T/E SKIN AT LOWER HINGE BS 1540. NO DENTS ALLOWED. FOUND OUT OF LIMITS IAW B727 SRM 55-40-1 FIG, 61. REMOVED LT T/E SKIN AT UPPER RUDDER BS 1540 IAW B727 SRM 51-30-2. FABBED LT T/E SKIN AT RUDDER BS 1540 MATERIAL USED 2024T3 .025 PO NR 9004384 DIM 45 3/4" BY 7" IAW B727 SRM 55-40-2 FIG 2. TREATED ALODINE AND PRIMED IAW B727 SRM 51-10-2. INSTALLED LT T/E SKIN AT UPPER RUDDER IAW B727 SRM 51-30-2.