What was found
LEFT INBD MID FLAP LWBL 85-100, LOWER T/E CHORD CRACKED THREE PLACES ON CUTOUTS. CUTOUT DAMAGE AREA 46.625" BY 2" IAW B727 SRM 51-40-3, FIG 1. FABRICATED NEW ANGLE FROM BAC1503-100046-7075T6, 46.625" BY 2" AND TWO EACH SPLICES FROM BAC 1503-100046-7075T6, 7.375" BY 2" IAW B727 SRM 51-40-3, FIG 1 AND 57-50-2, FIG 5. TREATED PRIMED AND INSTALLED PARTS IAW B727 SRM 51-10-2, 51-30-2 AND 57-50-2, FIG 5.