What was found
RIGHT WING, LWS 383.5, L/E SLAT AERO FENCE, LOWER AFT COMPOSITE SURFACE AREA IS CRACKED, LAYERS ARE SPLITTING. SANDED, CLEANED AND PREPPED 9" BY 5" DAMAGED AREA IAW B727 SRM 51-40-9, PAR 4, FIG 1. FABRICATED, IMPREGNATED (7781-50) FIBERGLASS AND 50A RESIN. INSTALLED FIBERGLASS PLIES AND CURED IAW B727 SRM 51-40-9, PAR 4, FIG 1.