As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
C2 DOOR CUTOUT AFT FRAME INNER CHORD IS CHORDED WITH EXFOLIATION BETWEEN STR 25R-26R. CUTOUT DAMAGED AREA IAW AD39-53-101 IR. FABRICATED NEW STRAP, FILLER, AND TWO ANGLES IAW DWG AD39-53-101IR. TREATED AND PRIMED ALL REPAIR PARTS AND AREA IAW B727 SRM 51-10-2. INSTALLED REPAIR PARTS IAW DWG AD39-53-101IR.