What was found
CRACK AT "S" INSIDE DUCT INLET, 6 O'CLOCK POSITION BS 1130. REMOVED FASTENERS FOR ACCESS IAW SRM 51-30-2 FIGURE 1. CUT OUT DAMAGE AREA 1" BY .75" ON "S" DUCT SKIN. CUT DAMAGE AREA ON STRAP 1" BY 15.25" IAW SRM 54-10-2 FIGURE 10. FABRICATED FILLER AND FABRICATED DOUBLER. FABRICATED TWO STRAP DOUBLERS IAW SRM 54-10-2 FIGURE 5 AND 54-10-3 FIGURE 10. PARTS AND AREA TREATED AND PRIMED IAW SRM 51-10-2 FIGURE 1. REPAIR AND STRAP INSTALLED IAW SRM 51-40-3 FIGURE 10 AT "S" DUCT INLET 6 O'CLOCK POSITION BS 1130.