What was found
DENT RT FUSELAGE SKIN BS 1220 ABOVE STRINGER 19R. EVALUATED DENT AND FOUND IT TO BE WITHIN LIMITS IAW SRM 53-30-1 FIGURE 1. HFEC SHOW CRACK AT DENT AREA IAW NDT PT 6 51-00-00 FIGURE 23. CUT OUT DAMAGE AREA IAW SRM 53-30-3 FIGURE 1. FABRICATED DOUBLER REPAIR IAW SRM 53-30-3 FIGURE 1 AND 53-30-2 FIGURE 3. TREATED AND PRIMED PART AND AREA IAW SRM 51-30-2. INSTALLED REPAIR IAW SRM 51-30-2 AND 53-30-3 FIGURE 1.