What was found
DENT, UNDERNEATH ELEVATOR SKIN PANEL AT ELEVATOR STATION 50.50 LT. CUT OUT DAMAGE AREA AT LT ELEVATOR LOWER SKIN IAW SRM 55-20-3 FIGURE 4. FABRICATED REPAIR DOUBLER IAW SRM 55-20-3 FIGURE 4 AND 55-20-3 FIGURE 1. PART AND AREA TREATED AND PRIMED IAW SRM 51-10-2 FIGURE 1. REPAIR DOUBLER INSTALLED AT LT ELEVATOR LOWER SKIN IAW SRM 55-20-3 FIGURE 4. CALCULATED REPAIR MOMENT "M" 0.066 TIMES 10.5" = 0.0693. ORIGINAL MOMENT WAS 120.189 + 0.0693 = NEW MOMENT OF 120.882, FOUND TO BE WITHIN LIMITS. NO FURTHER ACTION REQUIRED IAW SRM 51-80-7 PARA 2 FIGURE 1.