What was found
CRACK AT "S" INSIDE DUCT INLET 7 O'CLOCK POSITION BS 1130. REMOVED PREVIOUS REPAIR AND FILLER ON "S" DUCT AT 7 O'CLOCK POSITION BS 1130 IAW SRM 51-30-2 FIGURE 1. REMOVED FRAME IAW SRM 51-30-2 FIGURE 1. FABRICATED NEW FILLER FRAME. FABRICATED REPAIR DOUBLER IAW SRM 54-10-2 FIGURE 5 AND 54-10-3 FIGURE 10. PARTS AND AREA TREATED AND PRIMED IAW SRM 51-10-2 FIGURE 1. REPAIR AND FRAME INSTALLED IAW SRM 54-10-3 FIGURE 10.