What was found
LT RUDDER SKIN CRACKED 5" AT STA ZR 335.000 MAJOR REPAIR. PERFORMED MAJOR REPAIR IAW SRM 55-6-1 FIG 1 PG 2. REMOVED DAMAGED PANEL PLATING IAW SRM 55-1-0 PG 1, SRM 51-1-21, SRM 51-1-21A. FABRICATED PLATING AND BONDED DOUBLER BOTH FROM AL 2024T3 0.016" IAW SRM 55-6-1 FIG 1, PG 2 ITEM "A". BONDED BOTH PARTS IAW SRM 51-1-9, SRM 51-1-9A. CLEANED, TREATED AND PRIMED AREA AND PANEL PLATING IAW SRM 51-1-8B. INSTALLED NEW PANEL PLATING IAW SRM 51-1-21, SRM 51-1-21A. PERFORMED WEIGHT AND BALANCE IAW SRM 51-4-6 PG 1-6. FOUND WITHIN TOLERANCE 2563,8 INCH-LBS.