What was found
PPERFORMED DETAILED VISUAL INSPECTION AND FOUND A PREVIOUS REPAIR NOT IN ACCORDANCE WITH SRM. PERFORMED MAJOR REPAIR IAW SRM 53-2-1 FIG 7 SHEET 1, 4. REMOVED EXISTING NON STANDARD REPAIR IAW SRM 51-1-21, SRM 51-1-20D. FABRICATED REPAIR DOUBLER (AL7075T6 0.063") (2EA) INTERNAL FINGER DOUBLER (AL7075T6 0.032") IAW SRM 53-2-1 FIG 7 SHEET 1, 4, SRM 53-3-3 FIG 1 ITEM A. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS IAW SRM 51-1-8B. INSTALLED REPAIR PARTS IAW SRM 53-2-1 FIG 7 SHEET 1, 4, SRM 51-1-11, SRM 51-1-21, SRM 51-1-20D, SRM 51-3-1 (TORQUE). THIS IS A CLASS 1 REPAIR: INITIAL 4.000, REPETITIVE 4.000, REPLACEMENT N/A IAW SRM 53-2-1 FIG 5, TR NR 53-190 DATED 09-20-03. REINSPECT DUE AT 34.822 LANDING.