What was found
PERFORMED DETAILED VISUAL INSPECTION AND FOUND PREVIOUS REPAIR NOT IN ACCORDANCE WITH SRM. PERFORMED MAJOR REPAIR IAW SRM 53-2-1 FIG 7 SHEET 1, 5. REMOVED EXISTING NON STANDARD REPAIR IAW SRM 51-1-21, SRM 51-1-20D. CUT OUT DAMAGED SECTION AND FABRICATED REPAIR DOUBLER (AL7075T6 0.063") INTERNAL FINGER DOUBLER (AL7075T6 0.032") AND FILLER (AL7075T6 0.050") IAW SRM 53-2-1 FIG 7 SHEET 1, 5, SRM 53-5-3 FIG 1 ITEM "E". CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS IAW SRM 51-1-8B. INSTALLED REPAIR PARTS IAW SRM 53-2-1 FIG 7 SHEET 1, 5, SRM 51-1-11, SRM 51-1-21, SRM 51-1-20D, SRM 51-3-1 (TORQUE). THIS IS A CLASS 1 TYPE REPAIR: INITIAL 4.000, REPETITIVE 4.000, REPLACEMENT N/A IAW SRM 53-2-1 FIG 5, TR NR 53-1