What was found
MAIN CARGO COMPT FLOOR PANEL SUPPORT ANGLE CORRODED, STA 25.000 RBL 26 TO 42. REMOVED CORROSION IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW SRM 53-2-0 PG 2P. CUT OUT CORRODED ANGLE SEGMENT IAW SRM 53-2-0 PG 1. FABRICATED REINFORCING ANGLE (AL7075T6 0.063") AND FILLER (AL7075T6 0.050") IAW SRM 53-2-0 PG 1. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS IAW SRM 51-1-8B. INSTALLED REPAIR PARTS IAW SRM 51-1-21, SRM 51-3-0, SRM 51-3-1 (TORQUE).