What was found
RT WING ACCESS DOOR NR 505F INTERNAL DOUBLER HAS TWO CRACKS OF 0.500" AND 0.250" STA XRS 18.000 S-5 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 57-2-1 FIG 36. REMOVED FASTENERS IAW SRM 51-1-20D. CUT OUT DAMAGED SECTION IAW SRM 57-2-1 FIG 36. PERFORMED NDT INSPECTION IAW SRM 57-2-1 FIG 36 PG 133-134. NO CRACK OR CORROSION FOUND AFTER CUT OUT. ENCLOSED SMN FORM 242-4. FABRICATED EXT REPAIR DOUBLER (AL7075T6 0.160") INTERNAL DOUBLER (AL7075T6 0.063") AND FILLER (AL2024T3 511 0.375") IAW SRM 57-2-1 FIG 36. APPLIED POLYURETHANE TOP YELLOW COATING TO FILLER IAW SRM 51-1-12 PG 7-12. CLEANED, TREATED AND PRIMED AREA AND INTERNAL/EXTERNAL DOUBLER IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW SRM 5