What was found
EXTERNAL FUSELAGE FWD SVC DOOR JAMB FWD UPPER CORNER CRACKED 1.000 AT STA 160.000 L-11R - L-12R (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 14 SHEET 3, TR 53-181, DWG SRO8530021, DWG 5750776. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. TRIMMED OUT CRACKED AREA IAW SRM 53-2-0 FIG 14 SHEET 3, TR 53-181. FABRICATED FILLER (7075-T6AL 0.063), 2 EA DOUBLERS (7075-T6AL 0.063) (7075-T6AL 0.080) IAW SRM 53-2-0 FIG 14 SHEET 3, TR 53-181. CLEANED, TREATED AND PRIMED AREA, FILLER AND DOUBLERS IAW SRM 51-1-8B. APPLIED PRC SEALANT ON FAYING SURFACES IAW SRM 51-1-11 PG 9. INSTALLED DOUBLERS AND FILLER IAW SRM 53-2-0 FIG 14 SHEET 3, TR 53-181, SRM 51-1-20D PG 9, SRM 51-1-21 PG 1.