What was found
LT MLG WW L-24 FRAME FITTING CORRODED STA 879.000 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 8 SHEET 1, 3, 6. REMOVED CORROSION IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW SRM 53-2-0 FIG 1F SHEET 3. REMOVED CORRODED FRAME FITTING IAW SRM 51-1-20D. FABRICATED (4EA) SPLICES, (4EA) SHIMS BOTH FROM AL7075T7351, (1EA) DOUBLER FROM AL7075T651 0.125") (2EA) SHIMS FROM AL7075T651 0.071" IAW SRM 53-2-0 FIG 8 SHEET 1, 3, 6. HEAT TREATED DOUBLER AND SHIM FROM AL7075T651 TO 7075T6 IAW SRM 51-1-1 PG 13, 17. CUT OUT NEW FRAME FITTING IAW SRM 53-2-0 FIG 8 SHEET 1. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS IAW SRM 51-1-8B. INSTALLED REPAIR PARTS IAW SRM 53-2-0 FIG 8 SHEET 1, 3, 6, SRM 51-1-