What was found
STRUCTURE UNDER "A" CROSS-SLIDE CARGO DOOR, FITTING CRACKED 0.500" STA 320.000 L-27L. REMOVED CRACKED FITTING IAW SRM 51-1-20D. CUT OUT NEW FITTING AND FABRICATED REPAIR ANGLE (7075T6511 0.125") IAW SRM 53-2-0 FIG 2D. CLEANED, TREATED AND PRIMED AREA AND REPAIR ANGLE IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACE IAW SRM 51-1-11. INSTALLED REPAIR ANGLE AND FITTING IAW SRM 53-2-0 FIG 2D, SRM 51-1-20D, SRM 51-3-1 (TORQUE).