What was found
AFT CARGO COMPT FLOORBEAM 1/4" MISDRILLED HOLE AT STA 1040.000 RBL 56" (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 DATED 01-15-08 EVA D85300031 REV IR DATED 01-04-08 DWG AE85-53-102 REV IR DATED 01-03-08. REMOVED FASTENERS IAW SRM 51-1-20D. FABRICATED REPAIR ANGLE AND STRAP IAW DWG AE85-53-102 REV IR HEAT TREATED REPAIR ANGLE IAW SRM 51-1-1 PG 1-13.17 NDT INSPECTED REPAIR AND STRAP NO CRACK ANGLE NO CRACK FOUND IAW DPS 4.707-1. CLEANED, TREATED, PRIMED AREA AND REPAIR PARTS IAW SRM 51-1-8B. INSTALLED REPAIR PARTS IAW DWG NR AE85-53-102 REV IR SRM 51-1-20D SRM 51-3-1, SRM 51-3-0.