What was found
DURING C CHECK, AFT PIT BS 970 SHEAR TIE CORROSION BETWEEN STRINGER 29L AND 28L. FOUND CORROSION OUT OF LIMITS IAW SRM 53-10-1 FIG 1, CUT OUT DAMAGE AREA DIMENSION 6.5" BY 1" IAW SRM 51-10-1, 53-10-1 FIG 1 AND 53-10-4 FIG 11. FABRICATED SHEAR TIE REPAIR IAW SRM 51-20-2 FIG 5 AND 51-30-5, 53-10-4 FIG 11. ALODINE AND PRIMER REPAIR PART IAW SRM 51-10-2. INSTALLED NEW SHEAR TIE IAW SRM 53-10-4 FIG 11 ON SHEAR TIE.