What was found
DURING C CHECK, EXFOLIATION NOTED AT C2 DOOR CUT OUT, BS 990 (FRAME) BETWEEN STRINGERS 26R AND 27R. REMOVED CORROSION AT C2 DOOR CUT OUT BS 990 IAW SRM 51-10-6, ORIGINAL THICKNESS 0.100, MATERIAL LOSS 0.35, MATERIAL REMAINING 0.65, FOUND OUT OF LIMITS IAW SRM 53-10-2 FIG 5 AND 53-10-1 FIG 1. FABRICATED ANGLE REPAIR & FABRICATED REPAIR STRAP IAW COTNEY AEROSPACE DRAWING NR AE95-53-101 REV IR. TREATED AND PRIMED PARTS AND AREA IAW SRM 51-10-2. INSTALLED ANGLE REPAIR AT BS 990 BETWEEN STRINGERS 26R AND 27R IAW SRM 51-30-2 AND DRAWING NR AE95-53-101 WITH 8110-3 DATED 02/06/2008.