What was found
RT WING INBOARD L/E AREA AT FSS 107.2 FWD WING SPAR TERMINAL JOINT ANGLE CRACK AT BOTTOM. STOP DRILLED CRACK DIM .250 IAW B727 SRM 51-10-1. HFEC VERIFIED THAT CRACK END ON STOP DRILL HOLE IAW B727 NDTM PT6 51-00-00 FIG 23. FABRICATED NEW ANGLE USING 7075-T6 .063 PO NR 9006027 DIM 11 INCHES BY 2.25 IAW B727 SRM 51-20-1, 51-30-5 AND 57-10-2 FIG 3. INSTALLED NEW ANGLE IAW B727 SRM 51-30-2 AND 51-40-3 FIG 1.