What was found
DURING "C" CHECK FWD E/E COMPT BS 227.8 CORROSION ON WEB AND ANGLE BBL "0". REMOVED INTERCOSTAL DAMAGE, STIFFENER AND ANGLE FOR ACCESS IAW SRM 51-30-2. REMOVED CORROSION, FOUND OUT OF LIMITS IAW SRM 53-10-1 FIG 1. CUTOUT DAMAGED AREA APPROX 11 INCHES. FAB FILLER, 2 SPLICES IAW SRM 51-40-4 FIG 1. HEAT TREATED PARTS IAW FAS ENG REPORT 2-37153-801 REV A. TREATED, PRIMED AND INSTALLED PARTS REPAIR IAW SRM 51-10-2 AND 51-40-4 FIG 1. FAB NEW INTERCOSTAL IAW SRM 51-10-2 AND 51-30-2. MAJOR REPAIR, PERMANENT REPAIR